DACC CarbonManufacturing Technology

Testing and Certifications

  • HOME
  • Manufacturing Technology
  • Testing and Certifications

CT, Computed Tomography

X-ray computed tomography (X-ray CT) accurately examines various faults that are difficult to spot with regular X-ray photographs as it takes an X-ray tomography of a specific area of a laminated plate of the composite to display all aspects of the cross-section.

RT, Radiographic Test

RT, Radiographic Test

Scanning the laminated plates of composite with X-rays or γ-rays results in changes in the strength of transmitted x-rays depending on the shape of the laminated plate.
Injection of X-rays or γ-rays scanning to composite laminated plates. These changes in the intensity of X-ray are called X-rays' photosensitive reaction, fluorescence mechanism, and ionization reaction. It is possible to detect the defects and explore internal structures with this.

Equipment specification
Item Unit Specification
Maximum voltage of X-ray tube kV 225kV, 8mA
Max diameter of CT image field mm 275
Vertical limits of scan axis mm 880
CMM, Three Dimension Coordinate Measuring Machine

CMM, Three Dimension Coordinate Measuring Machine

It is possible to check the 3-dimensional measurements, geometry deviations, and shape precisions and enables an easy measuring of complex shapes and the free curves of products.

Equipment specification
Item Unit Specification
Measuring range mm X 700 x Y 700 x Z 600
Length measurement error μm 1.8+L/300
Scanning speed(Travel speed) mm/sec 125(70)
맨위로